The THD measurements at distance 315 mm and voltage levels 2 - 8 Volt were carried out with High Pass Filter "on" (2nd order Butterworth type, 50 Hz cutoff, HPF2-50)
The THD measurements at distance 315 mm and voltage level 11.2 Volt were carried out with High Pass Filter "on" (2nd order Butterworth type,850 Hz cutoff, HPF2-80)
The THD measurements at distance 20 mm and voltage levels 5.6 - 8 Volt were carried out with High Pass Filter "on" (2nd order Butterworth type, 20 Hz cutoff, HPF2-20)
Before taking the measurements the speaker had been very good boken-in